4951  - Isotech Netherlands  Sales

BRAND Isotech
Product 4951
Description ISOCAL - 6 Range
Internal code IMP4005288
Technical specification Product Highlights -45°C to 250°C. 35 x 160mm Volume Fast Response 35mm x 160mm Calibration Volume Calibrate Whole Measurement Loop Stability ±0.03°C Stability Blackbody ±0.03°C Surface Sensor ±0.5°C ITS-90 Cells ±0.0005°C Uniformity - Between Wells Dry Block Mode (Radial)Uniformity - Lower 40mm (Axial) Dry Block ModeUniformity - Radial Bath ModeUniformity - Lower 40mm (Axial) as Liquid BathHeating Time -30°C to 140°C: 15 mins Cooling Time 140°C to 0°C: 15 mins Calibration Volume 35 x 160mm Standard Insert 6 pockets, 2 x 4.5mm, 2 x 6.4mm, 1 x 8.0mm, 1 x 9.5mm diameter, all 157mm deep Insert Types Choice of three - See Accessories CJC Accuracy 0.35°C Dimensions 384H (including handle) x 212W x 312D mm Power 150 Watts Voltage 115Vac or 230Vac 50/60Hz 1 In ambient of 20°C: Min. Temperature is 65°C Below Ambient, Absolute Minimum -55°C 2 In ambient of 20°C: Min. Temperature is 55°C Below Ambient, Absolute Minimum -45°C 3 In ambient of 20°C 4 Dry Block Mode only: Comparing 4.5mm Well to Controller Display Value

Please Contact Us to Order to offer competitive prices and delivery time for Isotech - 4951 ISOCAL - 6 Range number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Netherlands Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Isotech

Jupiter S 650 Vor-Ort-Version

calibration system

KLEINKALIBRIERANLAGE ISOTECH HYPERION 2140 B MODELL 936

Model 936 as the basic version without reference thermometer for calibrating thermocouples in the temperature range of -45 ° C (-45 ° C under Ambient temperature) to + 140 ° C Calibration 65mm at 160mm immersion depth calibration depth 160mm absolute stability of ± 0.03 over 30 minutes Measurement uncertainty of up to ± 0.1 ° C otherwise after techn. Description in Datasheet incl. a traceable works certificate with RS 232 interface for setting and reading out display and controller with software CalNotePad Dimensions and weight see data sheet 220V / 50HZ Scope of supply: Hyperion, thermometer holder, magnetic stirrer, Cover, serial cable and Cal Notepad software Note: eXacal compatible

KLEINKALIBRIERANLAGE TYP ISOTECH ISIS

includes standard insert and insulating plug, serial communications and cal notepad Software and Traceable certificate, temp Range: -100'c to 40 'c

KLEINKALIBRIERANLAGE TYP ISOTECH JUPITER B PLUS

Dry Block Calibraincludes standard insert , 3 point traceable certificate , serial communications and cal notepad temp reng: 35 'c to 650 'c basic version tor

M210.

Milliohm meter

Artikel Nr.: 923

milliK Präzisionsthermometer

MODELL ISOTECH NEPTUN 915 H

30 ° C to 300 ° C Uncertainty: absolute ± 0.0005 ° C (with FP-cells)   vertical ± 0.003 ° C   ± 0.001 ° C in the vicinity of the   ambient temperature   to ± 0.001 ° C when compared calibration Liquid quantity: 7 liters Workspace: 100mm   400mm deep incl. RS 232 interface 240V - 50 Hz Further description gem. data sheet   

PEGASUS PLUS B 1200

High Temperature-Blockcalibrator

PEGASUS S 1200 ONSITE-VERSION

Temperature Range to 1200°C With standard Insert (Standard 4 x Ø 8 mm)853-06-01 Calibration volume: Ø 33,5 x 130mm Temperature Range: 150°C bis +1200°C Stabilität: ± 0,1°C Resolution: ± 1 Digit 220VAC - 50Hz, 1500W Referencethermocouple Type R (935-14-91) Software PC connecting cable, „RS232“

SEMI STANDARD 909/100H

ISOTECH 909H/Pt100 Temperature Range: -80°C to 550°C Wga > 1,11807 ITS-90 conditions Diameter: 6 mm Length: 480 mm Metal cover Cable length 2 m, Connecting terminal gold-plated. BNC connector

STANDARD KALIBRIEREINSATZ HYPERION & DRAGO

(Standard calibration insert for BlockkalibratorenHyperion and Drago. with the following holes: - 8 x 8 mm dia - 2 x 4.5 mm diameter)

TRANSPORTKOFFER

(Suitable for Isotech dry-wells with wheels and Trapeze handle.)

UMGEWÄLZTES FLUSSIGKEITSBAD

(Liquid container made of stainless steel)

CAL-SYS-R4-R7

Calibration, System (-80°C to 660°C)

1600 TYPE R 300

Normalthermoelement Modell

1600 TYPE S 300

Normalthermoelement Modell

1600 TYPE S 600

Normalthermoelement Modell

P/N: 530-5697 Type: IIT2302

Isolationsprüfgerät

937/50

Thermocouple Reference Unit

DJ-K

thermocouple cold junction

DJ-J

thermocouple cold junction

Other Category Brands

Contact us for request